Pressure Transmitter
Differential Pressure Transmitter
Electronic Pressure Switches
Pressure Level Transmitter
Overpressure And Vacuum Switches
Differential Pressure Switches
Digital Indicating Device
Force Cells
Pressure Measuring Cells
 
Huba Control Products

  Pressure transmitter

Pressure transmitter
Type 400

0 - 10 / 30 / 50 mbar

Pressure range gradation and executions see order code selection table
(PDF Datasheet)
  
Discription  



Technical data
Medium Air, neutral gases
Overload
200 mbar
Rupture pressure
500 mbar
Accuracy
Transmitter-type
10 mbar
30 mbar
50 mbar
Unit
 
Zero point tolerance
-
+ 1.5
+ 1.5
% fs
 
Tolerance at 0,5 mbar
+ 1.5
-
-
% fs
 
Tolerance full scale
+ 2.5
+ 1.5
+ 1.5
% fs
 
Linearity from 0.3 mbar on
+ 0.3
+ 0.2
+ 0.2
% fs
 
Long-term stability
+ 1
+ 0.5
+ 0.5
% fs
 
TCo typ.
+ 0.02
+ 0.02
+ 0.02
% fs/K
 
TCo max.
+ 0.04
+ 0.04
+ 0.04
% fs/K
 
TCe max.
+ 0.02
+ 0.02
+ 0.02
% fs/K
 
Positional error 0 - 90°
0.30
0.30
0.30
mbar
Materials Cover: polypropylene
in contact with medium Diaphragm: thermoplastic elastomer (TPE)
Temperature influences Medium and ambient temperature 0°C to + 70°C
  Storage temperature -10°C to +70°C
Dynamic response Response time: < 10 ms / Load cycle: < 10 Hz
Output and power supply A 5 VDC supply voltage is used for the factory calibration.
  Zero point at 10 % of supply voltage (0.5 V)
  Scale-end value at 70 % of supply voltage (3.5 V)
  With a variation in the supply voltage,
  the output signal responds ratiometrically.
  For a variation in supply voltage of + 0.5 %,
  the non-ratiometric proportion of the output signal
  is typically 1% of the scale end value (max. 2% )
  Other supply voltages and outputs on request.
Load RL > 50 kOhm; CL< 10 nF
Current consumption < 3 mA (with 50 kOhm load / 5 VDC supply voltage)
Electrical connections 3-pin connector, contact spacing 2.5 mm (Type AMP duoplug)
  Mechanically protected against polarity reversal
Copyright © 2008. ALM .
English Arabic French Spanish