Pressure Transmitter
Differential Pressure Transmitter
Electronic Pressure Switches
Pressure Level Transmitter
Overpressure And Vacuum Switches
Differential Pressure Switches
Digital Indicating Device
Force Cells
Pressure Measuring Cells
 

  Electronic pressure switches

Electronic pressure switches
    Type 616

0 - 25 bar

Pressure range gradation and executions see order code selection table
(PDF Datasheet)

  
Description  
  

Electronic Pressure Switches




Technical data
Overload See order code selection table
Rupture pressure 1.5 x ystem pressure
Accuracy Repeatability < +/- 0.5 % FS
  Accuracy of switching point adjustments < 1 % FS
Materials of housing Ceramic / Inox 1.4305
in contact Ceramic / PVDF
with the medium Sealing material: optionally FPM, EPDM, NBR, MVQ
  according to order code selection table
Temperature influences Medium and ambient temperature -15 °C up to +80 °C
  TC zero point, see order code selection table
  TC sensitivity:
  at 2x nominal pressure < +/- 0.015% FS/°C typ.
  at 3x nominal pressure < +/- 0.022% FS/°C typ.
  at 5x nominal pressure < +/- 0.037% FS/°C typ.
Load cycle < 50 Hz
Dynamic response Suitable for static and dynamic measurements.
  Response time < 5 ms
Power supply 10 ... 33 VDC / 24 VAC +/- 15 %
Output Open collector switch output for max. 100 mA at maximum supply voltage.
  NPN / PNP
  Short circuit proof and protected against polarity reversal.
  Each connection against other with max. +/- supply voltage.
Adjustment of The upper and lower switching point can be freely selected
switching points between 5 and 100% fs.
  Recommended spacing between upper and lower
  switching points: >2% fs
  (factory-set at 5 and 100 % unless switching point ist specified).
Operation / N/C contact:
Switch status indication When pressure is applied (p0 --> pmax) the collector will disconnect
  the applied load as soon as the upper switching point ist reached.
  As the pressure falls (pmax --> p0) the collector will connect the load
  as soon as the lower switching point is reached.
  N/O contact:
  When pressure is applied (p0 --> pmax) the collector will connect
  the applied load as soon as the upper switching point is reached.
  With a fall in pressure (pmax --> p0) the collector will disconnect the
  load as soon as the lower switching point is reached.
  Switch status indication
  LED in DIN connector (see accessories)