| Maximum
overpressure |
Maximum
overpressure and test pressure see setting
ranges |
| Lowest
turn-on pressure |
2
mbar / switching point and switching difference
adjustable. |
| |
Smallest switching
difference 1 mbar |
| Reproducibility |
+/-
5% of switching point with diaphragm material
type A, F, |
| |
+/-
10% of switching point with diaphragm material
FPM / EPDM |
| |
but as a minimum
+/- 0.6 mbar |
| Temperature
range |
Medium
and ambient temperature with diaphragm: |
| Case construction |
Switch case fiberglass-reinforced
plastic |
| Diaphragm |
A-NBR-based
/ C-FPM / E-EPDM / F-Silicone |
| |
Parts that come
into contact with the medium, to base |
| |
For vacuum switch
version also Polyacetal and Inox 1.4301 |
| Contact
material / |
Nominal
voltage type of current |
250 |
250 |
| Loading |
Nominal voltage for resistive
loading |
1 A |
6 A |
| |
Nominal
voltage for motor loading |
0.5
A |
3
A |
| |
AMP
tab connectors 6.3 mm |
| |
With cover: Cable
gland PG 11 |
| |
(for installation
arrangement electrical connections upward) |
| Service
life |
Mechanical
and electrical service life: |
| |
106
switching cycles, if the permitted switching
difference |