Pressure Transmitter
Differential Pressure Transmitter
Electronic Pressure Switches
Pressure Level Transmitter
Overpressure And Vacuum Switches
Differential Pressure Switches
Digital Indicating Device
Force Cells
Pressure Measuring Cells
 

  Pressure-type level sensing transmitter

Pressure-type level sensing transmitter
Type 700

0.8 - 10 bar

Pressure range gradation and executions see order code selection table
(PDF Datasheet)


Description  



Technical data
Overload 3x measuring range
Rupture pressure 3x measuring range
Accuracy Linearity (incl. hysteresis and repeatability) < +/- 0.5% fs
  Adjustment accuracy: Zero point +/- 1% fs
    Full scale +/- 1% fs
Application temperature Medium temperature -25 to +80 °C
  Storage -40 to +80 °C
Temperature influences Zero point (0 to 70 °C) +/- 0.03% fs/K
  Span (0 to 70 °C) +/- 0.015% fs/K
Dynamic response Response time < 2 msec.
  Suitable for static and dynamic measurements.
Output and power supply 0.5 - 4.5 V, ratiometric 5 VDC (4.75 - 5.25) 3-wire cable
Load > 10 k Ohm / < 100 nF
Ex-protection Ex II 2G EEx ia IIB T4
  Ex II 1G EEx ia IIB T4
Copyright © 2008. ALM .