Compact,
Low Cost, Explosion-proof and Weatherproof |
Model
1950 Explosion-Proof Differential Pressure Switch
combines the best features of the popular Dwyer®
Series 1900 Pressure Switch with an integral explosion-proof
and weatherproof housing,making it an exceptionalvalue
for either application.It is CE,UL and CSA listed,FM
approved for use in Class I,Div 1,Groups C and
D, Class II Groups E,F,and G and Class III hazardous
atmospheres (NEMA 7&9), Raintight (NEMA 3).Weatherproof
features include a drain plug and O-ring seal
in cover.Electrical connections are easily made
by removing front cover.For convenience the set
point adjustment screw is located on the outside
of the housing.Twelve models offer set points
from .03 to 20 ? w.c.(7.5 to 5 kPa)and from .5
to 50 psi (0.035 to 3.5 bar).The unit is very
light and compact about half the weight and bulk
of other explosion--proof or weather-proof switches
with separate enclosures.
|
Service:
Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Temperature Limits: -40 to 140°F
(-40 to 60°C); 0 to 140°F (-17.8 to 60°C)
for 1950P-8, 15, 25, and 50. -30 to 130°F
(-34.4 to 54.4°C) for 1950-02.
Pressure Limits:
Continuous: 1950’s - 45? w.c. (0.11 bar);
1950P’s - 35 psi (2.41 bar); 1950P-50 only
- 70 psi (4.83 bar). Surge: 1950’s - 10
psi (0.69 bar), 1950P’s - 50 psi (3.45 bar),
1950P-50 only - 90 psi (6.21 bar).
Enclosure Rating: IP64, NEMA
3, 7 and 9.
Switch Type: Single-pole double-throw
(SPDT).
Electrical Rating: 15 A @, 125,
250, 480 VAC, 60 Hz. Resistive 1/8 HP @ 125 VAC,
1/4 HP @ 250 VAC, 60 Hz.
Electrical Connections: 3 screw
type, common, normally open and normally closed.
Process Connections: 1/8? female
NPT.
Mounting Orientation: Diaphragm
in vertical position. Consult factory for other
position orientations.
Set Point Adjustment: Screw type
on top of housing.
Weight: 3.25 Ib (1.5 kg); 1950-02
model, 4.4 lb (2 kg).
Agency Approvals: CE, UL, CSA,
FM. |