Explosion-proof,
Weatherproof, Compatible with Natural Gases |
The
Model 1950G Explosion-Proof Switch combines
the best features of the popular Dwyer®
Series 1950 Pressure Switch with the benefit of
natural gas compatibility.Units are rain-tight
for outdoor installations,and are UL listed for
use in Class I,Groups A,B,C,&D;Class II,Groups
E,F,&G and Class III atmospheres,Directive
94/9/EC (ATEX)Compliant for 11 2 G EExd IIB &Hydrogen
T6 and CSA &FM approved for Class I,Div 1,Groups
B,C,D;Class II,Div 1,Groups E,F,G and Class III
atmospheres. The 1950G is very compact,about half
the weight and bulk of equivalent conventional
explosion-proof switches. Easy access to the SPDT
relay and power supply terminals is provided by
removing the top plate of the aluminum housing.A
supply voltage of 24 VDC,120 or 240 VAC is required.A
captive screw allows the cover to swing aside
while remaining attached to the unit.Adjustment
to the set point of the switch can be made without
disassembly of the housing.
|
Service:
Air and compatible combustible gases.
Wetted Materials: Contact Factory.
Temperature Limits: 0 to 140°F
(-17 to 60°Note: Set point drift may occur
with ambient temperature changes.
Pressure Limits: 45? w.c. (11.2
kPa) continuous; 10 psig (68.95 kPa) surge.
Enclosure Rating: IP64, NEMA
3, 7 and 9.
Switch Type: 1 Form C relay (SPDT).
Electrical Rating: 10A, 120/240
VAC, 28 VDC. Resistive 50mA, 125 VDC.
Power Requirements: 24 VDC ±10%.
120 240 VAC ±10% optional.
Electrical Connections: Internal
terminal block.
Process Connections: 1/8? female
NPT.
Mounting Orientation: Diaphragm
in vertical po-sition. Consult factory for other
position orientations.
Set Point Adjustment: Screw type
on top of housing.
Weight: 2 lb, 15.7 oz (1.35 kg).
Agency Approvals: CE, UL, CSA,
FM, ATEX. |