Series
608
Differential Pressure Transmitter
|
Ranges
Down to 0.1? w.c., Intrinsically Safe, NEMA 4X |
The
Series 608 Differential Pressure Transmitters
convert positive,negative (vacuum),or differential
pressures of clean,dry air or other non-conductive,non-corrosive
gases into a standard two wire,
4-20 mA output signal.The use of an ultra thin
silicon diaphragm enables precision measurement
of differential pressures as low as 0.1 ? of w.c.while
withstanding high static working pressures up
to 100 psig (6.89 bar).The Series 608 transmitters
are FM approved intrinsically safe for use in
the specified hazardous locations when used with
an approved intrinsic safety barrier.The rugged
NEMA 4X,stainless
steel housing makes this transmitter ideal for
use in industrial and process plant environments.
|
Service:
Clean/dry air and compatible, combustible gases.
(see Agency Approvals for FM ratings).
Wetted Materials: Consult factory.
Accuracy: ±0.5% or ±0.25%
full scale.
Stability: ±0.5% F.S./year.
Pressure Limits: 100 psig (6.89
bar); 15 psid (1.03 bar).
Temperature Limits: -20 to 185°F
(-28 to 85°C).
Compensated Temperature Range:
0 to 160°F (-18 to 71°C).
Thermal Effect: 0.5% Accuracy:
±0.02% F.S./°F;0.25%
Accuracy: ±0.01% F.S./°F.
Power Requirements: 12 to 36
VDC (2-wire).
Output Signal: 4-20 mA DC.
Zero and Span Adustments: Potentiometers
for zero and span.
Response Time: 250 ms.
Loop Resistance: DC: 0-1045 ohms
maximum.
Current Consumption: 4-20 mA.
Electrical Connections: Screw
terminal: Two 1/2? female NPT conduit.
Process Connections: Two 1/4?
female NPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Not position
sensitive.
Weight: 2 lb (0.9 kg).
Agency Approvals: FM approved
intrinsically safe for use in
Class I, Div. 1, Groups A, B, C, D; Class II,
Div. 1, Groups E, F, G;
Class III, Div. 1 when wired with approved intrinsically
safe barrier.
Entity parameters: V- = 36 VDC; I- = 250 mA; C
=12 nF; L =0 mH. |