Series
MS
Magnesense® Differential Pressure
Transmitter
|
Monitors
Pressure & Air Velocity |
The
Series MS Magnesense® Differential
Pressure Transmitter is an extremely
versatile transmitter for monitoring pressure
and air velocity. This compact package is loaded
with features such as: field selectable English
or metric ranges, field upgradeable LCD display,
adjustable dampening of output signal (with optional
display) and the ability to select a square root
output for use with Pitot tubes and other similar
flow sensors.Along with these features, the magnetic
sensing technology provides exceptional long term
performance and enables the Magnesense®
transmitter to be the solution for a myriad of
pressure and flow applications.
|
Service:
Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±1% for 0.25?
(50 Pa), 0.5? (100 Pa), 2? (500 Pa), 5? (1250
Pa), 10? (2 KPa), 15? (3 KPa), 25? (5 KPa) ±2%
for 0.1? (25 Pa), 1? (250 Pa) and all bi-directional
ranges.
Stability: ±1% / year
F.S.O.
Temperature Limits: 0 to 150°F
(-18 to 66°C).
Pressure Limits: 1 psi maximum,
operation; 10 psi, burst.
Power Requirements: 10 to 35
VDC (2-wire); 17 to 36 VDC or isolated 21.6 to
33 VAC (3-wire).
Output Signals: 4 to 20 mA (2-wire)
or 0 to 10 V (3-wire).
Response Time: Adjustable 0.5
to 15 sec. time constant. Provides a 95% response
time of 1.5 to 45 seconds.
Zero & Span Adjustments:
Digital push button.
Loop Resistance: Current output:
0-1250O max; Voltage output: min. load resistance
1 kO.
Current Consumption: 40 mA max.
Display (optional): 4 digit LCD.
Electrical Connections:
4-20
mA, 2-Wire: European Style Terminal Block
for 16 to 26 AWG.
0-10
V, 3-Wire: European Style Terminal, Block
for 16 to 22 AWG.
Electrical Entry: 1/2”
NPS Thread.
Accessory
(A-151): Cable Gland for 5 to 10 mm diameter cable.
Process Connections: 3/16”
ID tubing (5 mm ID). Maximum OD 9 mm.
Enclosure Rating: NEMA 4X (IP65).
Mounting Orientation: Diaphragm
in vertical position.
Weight: 8.0 oz (230 g).
Agency Approvals: CE.
|